Membrane degassing system GENO-MEC 500-2 (2-line) to remove CO2 Membrane degassing system (2 lines) for approx. 500 l/h permeate to remove the free carbon dioxide(CO2) by means of a membrane and stripping air. The compact module consists of hydrophobic pore membranes (hollow fibre modules with a high packing density) which are impermeable to water but let the gases pass through. The water to be degassed passes by the fibres. Due to the partial pressure gradient, the gas diffuses through the membrane. The water, on the other hand, is retained by the membrane. Membrane degassing system consisting of: 2 Degassing membrane units (PP) 1 Compressed air supply unit 1 Internal hosing made of PE/PA Dimensions: Length : approx. 290 mm (each module) Diameter : approx. 80 mm (each module) The 2-line membrane degassing system consists of 2 modules. Requirements to be provided by others on site: Amount of compressed air required : approx. 0.4-3.6 Nm³/h Supply of stripping gas (oil-free compressed air): 3 to 10 bar